Pdr-MU
Key features of this model: Measuring type: 4-wire three-phase current · Load: uneven load
This product is available on request only – we will quote price and delivery time.
- CEEU conformity
- ISO 9001:2015TÜV SÜD certified
Product description
- Measuring type
- 4-wire three-phase current
- Load
- uneven load
General data
| Dimensions | Housing B, (45 mm wide) Side A1 |
| Weight | 370 g |
Input
| Input variable | active power with alternating or three-phase current |
| Nominal values | |
| - apparent power | 50-150 % of apparent power |
| - alternating current | S = U x I |
| - three-phase current | S = U x I x 1,732 |
| Rated voltage | 100 V, 110 V, 230 V, 400 V, 500 V oder 600 V ± 20 %, max. 3,5 VA |
| Rated current | 1 A oder 5 A, 0,3 VA |
| Rated frequency | 50 Hz, 60 Hz or 400 Hz |
| Overload continuous | |
| - Current | 2-fold |
| - Voltage | 1.2-fold |
| Surge overload | |
| - Current | 20-fold, 1 sec |
| - Voltage | 2-fold, 1 sec |
Output
| Output variables | double output |
| Nominal values | 0-20 mA / 500 load and 0-10 V / max. 10 mA loadable |
| Option | "live zero" 4-20 mA / 500 load and 2-10 V max. 10 mA loadable (auxiliary voltage required) |
| Bipolar output | e.g. -20 ... 0 ... +20 mA / 500 load and - 0 ... 0 ... +10 V / max. 10 mA loadable |
| Zero point boost | e.g. 0-10-20 mA / 500 load and 0-5-10 V / max. 10 mA loadable |
Transmission behavior
| Accuracy | ± 0,5 % |
| Voltage influence | < 0.1 % at ± 10 % of nominal voltage |
| Frequency influence | < 0.3 % at 10 Hz frequency change |
| Phase angle influence | < 0.5 % at ± 90 ° |
| Temperature range | -15 °C to +20 °C to +30 °C to +55 °C |
| Temperature influence | < 0.3 % at 10 K |
| Auxiliary voltage influence | no |
| Load influence | no |
| External field influence | no |
| Residual ripple | < 30 mVpp |
| Response time | < 300 ms |
| Open circuit voltage | max. 24 V |
| Current limitation | max. 2-fold in case of overload |
| Test voltage | < 500 V: 4 kV between input, output, auxiliary voltage > 500 V: 5.2 kV between input and output 4 kV input / output to auxiliary voltage |
Auxiliary voltage
| (only for "live zero", fluctuating nominal voltage and voltages > 500 V) | |
| Standard | 230 V AC ± 20 %, 45-65 Hz, 2.5 VA |
| Options | 110 V AC ± 20 %, 45-65 Hz, 2.5 VA 24 V DC - 15 % to + 25 %, 2 W 6-30 V AC + DC, 2 VA 36-265 V AC + DC, 2 VA |
Installation
| Mounting | Snap-on mounting on top hat rail TH 35 according to DIN EN 60 715 |
| Electrical connection | Screw connection max. 4mm² |
- 70005-1306-9 – Pdr-MU @/5A A: 0-20mA und 0-10V @kW @V (ohne Hilfsspannung)
- 70005-1307-9 – Pdr-MU @/1A A: 0-20mA und 0-10V @kW @V (ohne Hilfsspannung)
- 70005-1308-9 – Pdr-MU @/5A A: 4-20mA und 2-10V @kW @V UH: 230V AC
- 70005-1309-9 – Pdr-MU @/1A A: 4-20mA und 2-10V @kW @V UH: 230V AC /Alternative zu CPR/3NV/I
- 70005-1310-9 – Pdr-MU @/5A A: 4-20mA und 2-10V @kW @V UH: 24V DC
- 70005-1311-9 – Pdr-MU @/1A A: 4-20mA und 2-10V @kW @V UH: 24V DC
- 70005-1319-9 – Pdr-MU @/1A A: 4-20mA und 2-10V @kW @V UH: 24V DC
- 70005-1321-9 – Pdr-MU @/1A A: 4-20mA und 2-10V @kW @V UH: 24V DC
Documents
Other models: Measuring transducer
- Pd-MU – Measuring type: 3-wire three-phase current · Load: uneven load
- Pnz-MU – Measuring type: 3-wire three-phase current · Load: Equal load
- Pw-MU – Current type: AC (alternating current) · Measuring type: Single phase alternating current
- Pz-MU – Measuring type: 4-wire three-phase current · Load: Equal load