Digital panel meters

Digital M series meters display readings as digits, monitor limit values and, on request, pass them on as a standard signal or via an interface. The choice depends on the input – from AC via current transformer to Pt100, thermocouple or shunt. The table leads to the instruments by input.

Sub-groups

Products

Which input – which instruments?

InputTaskInstruments
AC voltage / AC currentCurrent and voltage in the AC grid, true RMS, current via CT 1 A or 5 A6 types (AC4L, AC4EL, AC2L)
DC voltage / DC currentDC voltage up to 600 V DC, DC current, standard signals10 types (TD, DC4)
ShuntDC current via 60 mV or 150 mV shunt6 types (SR2, SR4)
Pt100Temperature with Pt100 RTD, 2-, 3- or 4-wire8 types
Pt1000Temperature with Pt10004 types
ThermocoupleTemperature with thermocouple7 types
ResistanceResistance measurement 1 kΩ to 1 MΩ10 types
PotentiometerPosition, travel and angle via potentiometer6 types
FrequencyFrequency, speed, pulses4 types
Current loopDisplay in the 4–20 mA loop, loop-powered2 types
Strain gauge weighing / melt pressureForce, weight and pressure via strain gauges2 + 2 types
Without inputDisplay for bus or interface2 types

The type designation names series and bezel width: M1.48 (48 mm, 4 digits), M1.72 and M1.96, M2.96 and M3.96 (96 mm, 5 digits), M3.48 (48 mm, 5 digits).

Display, limit values, outputs

The M1 instruments are 4-digit displays with 10 mm digits, configured via three front keys or the optional PC software, with limit monitoring on the display and only 54 mm mounting depth. M2 and M3 display 5 digits of 14 mm and offer as options an analogue output (e.g. 4–20 mA), digital input, setpoints – up to eight on the M3 – and, on the M3, RS232/RS485 interfaces and two analogue outputs.

AC current is measured via a current transformer with 1 A or 5 A secondary, DC current via a shunt – the guide on measuring DC explains how they work together. An analogue output turns the meter into a transducer for PLC and control system at the same time.

Digital or analogue?

Digital when limit values, standard signals, interfaces or several quantities are required. Analogue meters with a pointer remain the choice when the trend at a glance, robustness and operation without auxiliary supply matter. For energy and power in the three-phase grid there are energy meters, for running times hour meters.

Frequently asked questions

Which digital meter do I need for a current transformer?

An instrument from the AC voltage/AC current group with 1 A or 5 A input, e.g. the M2.96-145 AC4EL. The CT ratio is set on the instrument, the display then shows the primary current.

Can a digital meter output 4–20 mA?

Yes, as the analogue output option on the M2 and M3 series – two outputs on the M3. The display then replaces a separate transducer.

Which bezel sizes are available?

48 mm (M1.48, M3.48), 72 mm (M1.72) and 96 mm (M1.96, M2.96, M3.96). Cut-outs are in the datasheet of each type.

How is the instrument configured?

Via the front keys during operation – limit values can be adjusted directly – or via the optional PC software.

Are there instruments with an interface?

Yes, the M3 series optionally with RS232 or RS485. Instruments without measuring input serve as pure displays for bus and interface.