IER-1
Protective current transformer
Article features
- This protective current transformer is used for system protection in conjunction with the appropriate switching devices
- Available in numerous protection classes
- Sealable secondary terminal covers made of clear polycarbonate
- Double secondary terminals on all versions for short-circuiting the secondary windings before opening the secondary circuit
- Round conductor
- Ø 80 mm
- Dimensions (W × H × D)
- 133 × 155 × 46 mm
- Rated current
- 300, 500, 600, 750, 800, 1000, 1200, 1500, 1600, 250, 400, 2000 A
- Instrument security factor
- FS 5
| Round conductor | Ø 80 mm |
| Dimensions (W × H × D) | 133 × 155 × 46 mm |
| Rated current | 300, 500, 600, 750, 800, 1000, 1200, 1500, 1600, 250, 400, 2000 A |
| Instrument security factor | FS 5 |
Conditions of use
| Secondary current | 5 A oder 1 A |
| Nominal frequency | 50 - 60 Hz |
| max. permissible operating voltage | 720 V |
| Test voltage | 3 kV / 1 min |
| Thermal rated continuous current | Icth = 1,2 x Ipr |
| Thermal rated short-time withstand current | Ith = 60 x Ipr |
| Rated impulse current | Idyn = 2,5 x Ith |
| Overcurrent rating (FS) | n < 5 |
| Insulation class | E / F / H |
| Normative standards | IEC 61869 Teil 1 + 2 / DIN EN 42600 |
| Housing | Gehäuse aus selbstverlöschendem PA66 V0 nach UL 94 |
Environmental conditions
| Installation location | Indoor use |
| Ambient temperature (operation) | -40°C ... +60°C |
| Ambient temperature (storage / transport) | -40°C ... +60°C |
| Altitude | up to 1000 m |
Types
| Output | Cl. | Rated current A | VA | ||||
|---|---|---|---|---|---|---|---|
| 250 | 300 | 400 | 500 | 600 | |||
| 1 A | 5P5 | ||||||
| 5P10 | – | ||||||
| 10P5 | |||||||
| 10P10 | |||||||
| 5 A | 5P5 | ||||||
| 5P10 | – | ||||||
| 10P5 | |||||||
| 10P10 | |||||||
| 750 | 800 | 1000 | 1200 | 1500 | VA | ||
| 1 A | 5P5 | ||||||
| 5P10 | |||||||
| 10P5 | |||||||
| 10P10 | |||||||
| 5 A | 5P5 | ||||||
| 5P10 | |||||||
| 10P5 | |||||||
| 10P10 | |||||||
| 1600 | 2000 | VA | |||||
| 1 A | 5P5 | ||||||
| 5P10 | |||||||
| 10P5 | |||||||
| 10P10 | |||||||
| 5 A | 5P5 | ||||||
| 5P10 | |||||||
| 10P5 | |||||||
| 10P10 | |||||||
| Output | Cl. | Rated current A | |
|---|---|---|---|
| 250 | 300 | ||
| 1 A | 5P5 | ||
| 5P10 | – | ||
| 10P5 | |||
| 10P10 | |||
| 5 A | 5P5 | ||
| 5P10 | – | ||
| 10P5 | |||
| 10P10 | |||
| 400 | 500 | ||
| 1 A | 5P5 | ||
| 5P10 | |||
| 10P5 | |||
| 10P10 | |||
| 5 A | 5P5 | ||
| 5P10 | |||
| 10P5 | |||
| 10P10 | |||
| 600 | 750 | ||
| 1 A | 5P5 | ||
| 5P10 | |||
| 10P5 | |||
| 10P10 | |||
| 5 A | 5P5 | ||
| 5P10 | |||
| 10P5 | |||
| 10P10 | |||
| 800 | 1000 | ||
| 1 A | 5P5 | ||
| 5P10 | |||
| 10P5 | |||
| 10P10 | |||
| 5 A | 5P5 | ||
| 5P10 | |||
| 10P5 | |||
| 10P10 | |||
| 1200 | 1500 | ||
| 1 A | 5P5 | ||
| 5P10 | |||
| 10P5 | |||
| 10P10 | |||
| 5 A | 5P5 | ||
| 5P10 | |||
| 10P5 | |||
| 10P10 | |||
| 1600 | 2000 | ||
| 1 A | 5P5 | ||
| 5P10 | |||
| 10P5 | |||
| 10P10 | |||
| 5 A | 5P5 | ||
| 5P10 | |||
| 10P5 | |||
| 10P10 | |||
Click an article number to request that variant directly.
Documents
neutral · manufacturer-independent
Neutral specification text for direct use in your tender – without type or manufacturer.
Protection current transformer (cable or busbar type) for protection purposes to IEC 61869-1+2 (formerly IEC 60044-1), DIN VDE 0414. For plant and line protection in combination with protection relays. Rated operating voltage 0.72 kV, insulation class E.
- Accuracy / protection class: ______________
- Rated primary current: ______ A
- Rated secondary current: ______ A
- Rated burden: ______ VA
Guaranteed accuracy limit factor (ALF) according to the protection class. Encapsulated, finger-safe design, including mounting material.
To be supplied and installed ready for operation.
Selected product:
Manufacturer: ___________________ Type: ____________