Hour meters: how they count, how they are connected, which one fits
An hour meter counts the time during which voltage is present at its terminals. It is connected in parallel with the motor, pump, compressor or the contactor that switches the plant on – when the plant runs, the meter runs. This yields the operating hours for maintenance intervals, oil changes, warranty and rental billing.
The CELSA meters BZ48, BZ72 and BZ96 count up to 99999.99 hours with two decimals, non-resettable, and are designed for 48 × 48 mm, 72 × 72 mm and 96 × 96 mm cut-outs; the BZ48 can also be snapped onto a DIN rail to DIN 50022. The BZ48 front is sealed to IP65, BZ72 and BZ96 have IP52.
The supply voltage is decisive: 230 V AC (formerly 220 V) at 50 Hz or 60 Hz, 115 V, 24 V 50 Hz, 440 V 60 Hz for the BZ72s, and DC 10–80 V (for 24 V DC) and 80–220 V DC. The meter does not measure the voltage, only its duration – with AC the mains frequency clocks it, which is why the frequency is fixed in the type.
Which hour meter fits?
| Type | Mounting | Front | Voltages | Range |
|---|---|---|---|---|
| BZ48, BZ48/A | 48 × 48 mm, clip; also DIN rail | IP65 | 230 V 50/60 Hz, 115 V 50/60 Hz, 24 V 50 Hz, 10–80 V DC, 80–220 V DC | 99999.99 h |
| BZ72, BZ72s | 72 × 72 mm, metal bracket | IP52 | 230 V 50 Hz; BZ72s 230 V 60 Hz, 440 V 60 Hz | 99999.99 h |
| BZ96, BZ96s | 96 × 96 mm, metal bracket | IP52 | 230 V 50 Hz; BZ96s 115 V 60 Hz | 99999.99 h |
Digit height 4 mm, supply tolerance ±10 % for the AC types. The version is part of the article name, e.g. “BZ48 230V 50Hz AC”.
Calculators and related pages
Typical Applications
- Maintenance intervals on pumps, compressors and motors
- Runtime evidence for warranty and rental
- Operating hours of standby generators and heating systems
Recommended Products
FAQ
How is an hour meter connected?
In parallel with the load or contactor coil whose running time is to be counted – two terminals, no polarity with AC. With DC observe plus and minus as per the connection diagram. When voltage is present, the meter counts.
Which meter do I take for 220 V?
The 230 V types: the low-voltage grid was changed from 220 V to 230 V, the meters tolerate ±10 % and therefore also run on older 220 V systems. BZ48, BZ72 and BZ96 are available for 230 V 50 Hz, BZ48 also for 60 Hz.
Are there hour meters for 24 V DC?
Yes, the BZ48 10–80 V DC – it covers 24 V DC and runs on all DC voltages from 10 V to 80 V. For higher DC voltages there is the BZ48 80–220 V DC, for 24 V AC the BZ48 24 V 50 Hz.
Does the meter fit on a DIN rail?
The BZ48 snaps onto a DIN rail to DIN 50022 and can equally be fitted into a 48 × 48 mm cut-out. BZ72 and BZ96 are panel-mount units with metal bracket.
Can the meter be reset?
No, the BZ meters are non-resettable – that makes the hours reliable as evidence for maintenance, warranty or rental. The counter runs to 99999.99 h.
Why is the frequency stated in the type?
The AC meters are clocked by the mains frequency. A 50 Hz meter on 60 Hz counts too fast. That is why there are separate versions for 50 Hz and 60 Hz; DC types have their own time base.